中国·美高梅(1888·MGM)官方網站-APP platform

EN/CN

Product

S1600

Characteristic

● Excellent tracking resistance,CTI≥600V
● UV   Blocking
● Good PCB processablity
● Not recommended fro solder mask rework


Application Area

● PDP, LCD, power base board, TV, refrigerator, washing machine, and etc.
● Not suitable for Anti-CAF application
  • Product Performance
  • Product Certificate
  • Data Download
Items Method Condition Unit Typical Value
Tg IPC-TM-650 2.4.25 DSC 135
Td IPC-TM-650 2.4.24.6 5% wt. loss 310
CTE (Z-axis) IPC-TM-650 2.4.24 Before Tg ppm/℃ 55
After Tg ppm/℃ 308
50-260℃ % 4.5
Thermal Stress IPC-TM-650 2.4.24.13 288℃, solder dip -- >100S  No Delamination
Volume Resistivity IPC-TM-650 2.5.17.1 After moisture resistance MΩ.cm 5.0E + 08
E-24/125 MΩ.cm 5.0E + 06
Surface Resistivity IPC-TM-650 2.5.17.1 After moisture resistance 5.0E + 07
E-24/125 5.0E + 06
Arc Resistance IPC-TM-650 2.5.1 D-48/50+D-4/23 s 126
Dielectric Breakdown IPC-TM-650 2.5.6 D-48/50+D-4/23 kV 60
Dissipation Constant (Dk) IPC-TM-650 2.5.5.9 1MHz -- 4.7
IEC 61189-2-721 10GHz --
Dissipation Factor (Df) IPC-TM-650 2.5.5.9 1MHz -- 0.016
IEC 61189-2-721 10GHz --
Peel Strength (1oz HTE copper foil) IPC-TM-650 2.4.8 A N/mm
After thermal Stress 288℃,10s N/mm 1.8
125℃ N/mm 1.6
Flexural Strength LW IPC-TM-650 2.4.4 A MPa 550
CW IPC-TM-650 2.4.4 A MPa 450
Water Absorption IPC-TM-650 2.6.2.1 E-1/105_D-24/23 % 0.10
CTI IEC60112 A Rating PLC 0
Flammability UL94 C-48/23/50 Rating V-0
E-24/125 Rating V-0

Remarks:

1. Specification sheet: IPC-4101/21, is for your reference only.

2. All the typical value is based on the 1.6mm specimen,while the Tg is for specimen≥0.50mm.

3. All the typical value listed above is for your reference only,please turn to Shengyi Technology Co., Ltd. for detailed information, and all rights from this data sheet are reserved by Shengyi Technology Co., Ltd.

Explanations: C=Humidity conditioning, D=Immersion conditioning in distilled water, E=Temperature conditioning

The figures following the letter symbols indicate with the first digit the duration of the preconditioning in hours, with the second digit the preconditioning temperature in ℃ and with the third digit the relative humidity.